Home
Categories
Send inquiry
Home
Products
Power Cable Accessories
200A Cable Accessories
250A Cable Accessories
600A Cable Accessories
630A Cable Accessories
Elbow Surge Arrester Connector
Lightning Surge Arrester
Mov Lightning Arrester
Lightning Arrester Spare Part
lightning arrester accessories
Shrink Tube
Heat Shrinkable Tube
Cold Shrinkable Tube
LV Shrink Tube Series
Pad Mounted Transformer Components
Fuse
Loadbreak Switch
Indicator
Meters For Transformer
Other Spare Parts For Transformer
Current And Potential Transformer
10kV Currnet Transformer
10kV Potential Transformer
20-35kV Current Transformer
Busbar Type Current Transformer
Discharge Coil
Fuse Potential Transformer Series
Pole-Mounted Current Transformer
Pole-Mounted Potential Transformer
MV Switchgear Component
Ring Main Unit Operating Mechanism
Vacuum Circuit Breaker With Isolator
Ring Main Unit Loadbreak Switch
Vacuum Interrupter
Ring Main Unit Spare Part
Dropout Fuse Cutout
News
FAQs
About Us
Factory Tour
Contact Us
Home
Products
Power Cable Accessories
200A Cable Accessories
250A Cable Accessories
600A Cable Accessories
630A Cable Accessories
Elbow Surge Arrester Connector
Lightning Surge Arrester
Mov Lightning Arrester
Lightning Arrester Spare Part
lightning arrester accessories
Shrink Tube
Heat Shrinkable Tube
Cold Shrinkable Tube
LV Shrink Tube Series
Pad Mounted Transformer Components
Fuse
Loadbreak Switch
Indicator
Meters For Transformer
Other Spare Parts For Transformer
Current And Potential Transformer
10kV Currnet Transformer
10kV Potential Transformer
20-35kV Current Transformer
Busbar Type Current Transformer
Discharge Coil
Fuse Potential Transformer Series
Pole-Mounted Current Transformer
Pole-Mounted Potential Transformer
MV Switchgear Component
Ring Main Unit Operating Mechanism
Vacuum Circuit Breaker With Isolator
Ring Main Unit Loadbreak Switch
Vacuum Interrupter
Ring Main Unit Spare Part
Dropout Fuse Cutout
News
FAQs
About Us
Factory Tour
Contact Us
Featured
Home
Products
Lightning Surge Arrester
lightning arrester accessories
Panel Type Fault Indicator
Product Detail
General:
The short-circuit current sensor and the ground current sensor are respectively connected with the panel instrument main body through the optical fiber. After the failure. the sensor
transmits the signal to the panel mainframe host through the optical fiber to judge.
Installation Position:
• Installed at the first substation outlet of the long line of the cable): it can be judged that there is a fault in the station or outside the line;
• Installed in the user into the transformer into high-voltage line: to determine whether the failure caused by the client;
• Installed in the overhead line and cable connection: to distinguish whether the fault occurred in the cable side;
• Installed on the outlet side of high-voltage switchgear or ring main unit: can judge the outlet fault branch.
Features:
1、for the failure of the line during troubleshooting troubleshooting to provide help and convenience.
2、according to the size of line load and line distribution of the situation, the rational development of fault indicator installatior、location.
3、the line normal operation. the indicator is in the reset state. without any indication.
4、when the line release short-circuit or ground fault, the line fault repair personnel according to the indicator flash status to troubleshoot areas where the fault
5, the product reset time Factory default time is 12h (reset time can be adjusted according to customer needs).
6、the product troubleshooting for the line to provide a powerful help, easy to find fault location;
7、to shorten the power outage time, and further improve the power supply;
8、product installation without power outages, free professional installation tools, demolition convenience.
Product Tags
Lightning Arrester Sparepart
Panel Type Fault Indicator Related Video:
Related Products
monitor for lightning arrester
Overhead in Fault Indicator
lightning counterOutdoor Lightning Co...