Home
Categories
Send inquiry
Home
Products
Power Cable Accessories
200A Cable Accessories
250A Cable Accessories
600A Cable Accessories
630A Cable Accessories
Elbow Surge Arrester Connector
Lightning Surge Arrester
Mov Lightning Arrester
Lightning Arrester Spare Part
lightning arrester accessories
Shrink Tube
Heat Shrinkable Tube
Cold Shrinkable Tube
LV Shrink Tube Series
Pad Mounted Transformer Components
Fuse
Loadbreak Switch
Indicator
Meters For Transformer
Other Spare Parts For Transformer
Current And Potential Transformer
10kV Currnet Transformer
10kV Potential Transformer
20-35kV Current Transformer
Busbar Type Current Transformer
Discharge Coil
Fuse Potential Transformer Series
Pole-Mounted Current Transformer
Pole-Mounted Potential Transformer
MV Switchgear Component
Ring Main Unit Operating Mechanism
Vacuum Circuit Breaker With Isolator
Ring Main Unit Loadbreak Switch
Vacuum Interrupter
Ring Main Unit Spare Part
Dropout Fuse Cutout
News
FAQs
About Us
Factory Tour
Contact Us
Home
Products
Power Cable Accessories
200A Cable Accessories
250A Cable Accessories
600A Cable Accessories
630A Cable Accessories
Elbow Surge Arrester Connector
Lightning Surge Arrester
Mov Lightning Arrester
Lightning Arrester Spare Part
lightning arrester accessories
Shrink Tube
Heat Shrinkable Tube
Cold Shrinkable Tube
LV Shrink Tube Series
Pad Mounted Transformer Components
Fuse
Loadbreak Switch
Indicator
Meters For Transformer
Other Spare Parts For Transformer
Current And Potential Transformer
10kV Currnet Transformer
10kV Potential Transformer
20-35kV Current Transformer
Busbar Type Current Transformer
Discharge Coil
Fuse Potential Transformer Series
Pole-Mounted Current Transformer
Pole-Mounted Potential Transformer
MV Switchgear Component
Ring Main Unit Operating Mechanism
Vacuum Circuit Breaker With Isolator
Ring Main Unit Loadbreak Switch
Vacuum Interrupter
Ring Main Unit Spare Part
Dropout Fuse Cutout
News
FAQs
About Us
Factory Tour
Contact Us
Featured
Home
Products
Dropout Fuse Cutout
dropout fuse YK3 series
Product Detail
General
Fuse Cutout is a kind of outdoor high voltage of the distribution transformer or distribution lines and primarily used to protect transformers or lines against the impact raised by short circuit , overload and switching current . The drop - out fuse cutout is composed of insulator support and a fuse carrier , static contacts that are fixed on two sides of insulator support and moving contact installed on two ends of fuse carrier . The interior of the fuse carrier is the extinguishing tube while the exterior is made of phenolic compound paper tube or epoxy glass .
During normal operation , the fuse link is tightened to form the closing position . In fault current situation , the fuse link melts and an electrical arc is formed . The arc - extinguishing tube is heated and explosion of gas occurs which causes high pressure inside the fuse carrier tube and makes the tube to separate from the contacts . The contact is relaxed once the fuse element melts .
The fuse cutout is now in the open position , the operator needs to switch the current off . The moving contact can be pulled off by an insulated hot sticker . The main contact and auxiliary contact are connected .
Structure
Conditions of Application
Ambient environment:
1.Temperature:-40
℃≤
T
≤
-40
℃
2.Altitude above sea level:
≤
1000m
3.Max.wind speed:
≤
35m/s
4.Earthquake intensity:
≤
8 degree
Product Tags
Drop-Out Fuse Cutout、Dropout Fuse、Fuse
dropout fuse YK3 series Related Video:
Related Products
HV Dropout Fuse Cutout AH-11
Dropout Fuse YK2 Series
HV Dropout Fuse Cutout AH-19
HV Dropout Fuse Cutout AH-16
HV Dropout Fuse Cutout AH-7
HV Dropout Fuse Cutout AH-22